IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 is a genuine OEM primary high-limit switch rated to open at approximately 150°F, built for the GMH950703BXAB gas furnace and compatible Goodman/Amana units. This normally-closed thermal safety control monitors heat-exchanger/plenum temperature and shuts off the burners if the furnace overheats — protecting against restricted airflow, dirty filters, or blower failure. A tripped or failed limit switch is a common cause of short-cycling and no-heat calls.
OEM limit switches carry the exact trip temperature and mounting footprint Goodman engineered for this furnace. Generic switches with different set points can nuisance-trip or fail to protect the heat exchanger. For a safety-critical control, choose OEM.
Easy (1/5) — Two spade terminals and typically two mounting screws. Cut power at the breaker before replacing. A multimeter confirms continuity for diagnosis.