IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 Primary Limit Switch is a genuine OEM high-limit safety control with a 150°F trip point, built for the GKS90905DXAC furnace. Mounted on the heat-exchanger plenum, it monitors supply-air temperature and shuts off the gas valve if the furnace overheats — typically due to restricted airflow, a dirty filter, or a failed blower — protecting the heat exchanger from cracking.
The 150°F rating is matched to this furnace's cabinet and airflow design. The OEM 20162903 delivers the exact trip temperature, probe length, and terminal layout Goodman specified. Generic limits with a different rating or probe depth can nuisance-trip or, worse, fail to protect the heat exchanger. OEM is the recommended choice for this safety control.
Easy (1 of 3). Disconnect power, remove the two mounting screws, transfer the wire terminals, and seat the new switch so the probe sits in the airstream. If the old limit was tripping, correct the airflow restriction first — replacing the switch alone won't fix an overheating furnace.