IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 is a genuine OEM primary limit switch rated at 150°F, designed for the AMVC80604BNAA gas furnace. Mounted on the heat-exchanger bulkhead, it monitors supply-air temperature and opens the control circuit if the blower fails or airflow is restricted, protecting the heat exchanger from cracking due to overheating. A furnace that short-cycles on high limit or shuts down after a few minutes of heat often needs this switch.
The 150°F trip point is model-specific; installing a generic limit with a different rating can allow dangerous heat-exchanger temperatures or cause constant nuisance trips. OEM guarantees the correct set point and flange fit.
Difficulty: Easy (2/5). Cut power, photograph wiring, remove two screws, swap the spade connectors, and reseat against the heat-exchanger panel. Confirm normal cycling. Typical time: 10–15 minutes.