The Goodman 20162903 is a genuine OEM primary high-limit switch rated to open at 150°F, designed for the AMH81405DXCA gas furnace and compatible Goodman and Amana units. Mounted on the heat exchanger or blower deck, this normally-closed safety control monitors supply-air temperature and shuts off the burners if the furnace overheats — protecting the heat exchanger, ductwork, and your home from unsafe temperatures.
The OEM switch is calibrated to the exact trip point specified for this furnace's airflow and heat-exchanger design. A generic limit switch with a different set point can trip too early (short cycling, no heat) or too late (a real safety risk). Because this is a life-safety control, the genuine 150°F OEM part is the correct choice.
Easy to Moderate — Turn off power, remove two mounting screws and the spade wire connectors, and swap in the new switch. Match orientation and terminal positions. Typically a 15–20 minute job for a comfortable DIYer.