The Goodman B1370198 Primary Limit Switch is a genuine OEM high-limit safety control for AMH81405DXAA gas furnaces and compatible Goodman/Amana equipment. Mounted on the heat-exchanger blower deck, this switch monitors supply-air temperature and opens at roughly 150°F to de-energize the gas valve when the furnace overheats due to a dirty filter, closed dampers, or blower failure.
Genuine B1370198 switches ship with the correct 150°F calibration and factory mounting flange that seats precisely against the blower housing for accurate temperature sensing. Generic replacements often sense temperature inaccurately or use the wrong bracket, causing premature lockouts or delayed safety response. Because this component directly controls the gas valve, we recommend the authentic OEM part.
Easy (1/5). Kill power at the furnace disconnect, disconnect the two spade terminals, remove the mounting screws, and install the new B1370198 in the same orientation. Reconnect the leads and restore power. Typical replacement takes 10–15 minutes with a nut driver. Confirm the switch resets and the furnace completes a full heat cycle after service.
Get your furnace heating safely again with the genuine Goodman B1370198.