The Goodman B1370198 is a genuine OEM primary high-limit switch rated at 150°F for AMH81405DNAC gas furnaces. Installed on the heat-exchanger/supply-air side, this auto-reset limit monitors plenum temperature and shuts off the burners if the furnace overheats due to insufficient airflow, protecting the heat exchanger from cracking. It is a factory-spec replacement that fits Goodman and Amana furnaces built on the same chassis.
The genuine OEM B1370198 delivers the exact 150°F trip point and mounting geometry the furnace's safety design depends on. Generic limits with different set points or footprints can nuisance-trip or, worse, allow the heat exchanger to overheat. For a primary safety limit, OEM is strongly recommended.
Easy to Moderate — disconnect power, remove the mounting screws and spade terminals, and fit the replacement in the same location and orientation. Diagnose and correct any airflow restriction before returning the furnace to service.