IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 is a genuine primary high-limit switch rated to trip at 150°F, designed for AMH81205DNBB gas furnaces and related Goodman/Amana models. Mounted on the heat-exchanger or blower deck, it continuously monitors supply-air temperature and interrupts the burner circuit if the furnace overheats — most often a sign of low airflow from a dirty filter, closed registers, or a failing blower.
The trip temperature and mounting geometry must match the furnace exactly. The OEM 20162903 is factory-calibrated to 150°F for this cabinet, whereas a generic switch with the wrong setpoint can cause nuisance lockouts or allow unsafe overheating. For high-limit protection, OEM is the safe choice.
Easy. About 10–20 minutes: disconnect power, pull the two spade connectors, remove two mounting screws, and install the replacement in the same orientation. If the limit had been tripping, correct the airflow restriction before returning the unit to service.