IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 Primary Limit Switch (150°F) is a genuine OEM high-limit safety control for AMH80805CNBA gas furnaces. Mounted on the heat-exchanger or blower deck, the primary limit monitors supply-air temperature and shuts off the burners if the furnace overheats — typically from restricted airflow, a dirty filter, or a failing blower. Its 150°F set point keeps the heat exchanger within safe operating temperature and protects the appliance and ductwork.
The genuine OEM 20162903 ships with the correct 150°F calibration, insertion depth, and mounting flange for this furnace. Generic limits with a different set point or probe length can nuisance-trip on normal heating cycles or delay shutdown during a real fault. As a safety device, OEM is the recommended choice.
Easy (2/5). Disconnect power, unplug the wire terminals, remove the two mounting screws, and install the new limit with the sensing element in the same position. Confirm the airflow issue behind any repeat trips before returning the furnace to service. Recommended for a qualified HVAC technician.