IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 Primary Limit Switch is a genuine OEM high-temperature safety control for the Amana/Goodman AMEH800805CNAA gas furnace. This normally-closed thermal switch opens at approximately 150°F to cut power to the gas valve if the heat exchanger overheats — a critical safety device that protects against cracked heat exchangers and fire hazards from restricted airflow or blower failure.
This is a factory-calibrated OEM switch with the exact trip point and mounting bracket your furnace requires. Because a limit switch is a safety component, using the correct OEM trip temperature is essential — a generic switch with the wrong setpoint can nuisance-trip (short cycling) or, worse, fail to protect the heat exchanger. Insist on OEM for safety-critical controls.
Easy (2/5). Cut power, remove the two mounting screws, disconnect the spade terminals, and swap in the new switch. Roughly a 10–15 minute repair. Always confirm proper airflow and filter condition, since a tripping limit often signals an underlying airflow problem.