IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 Primary Limit Switch is a genuine OEM high-limit safety control rated at 150°F for the GKS90905DXAE gas furnace. Mounted on the heat-exchanger or blower bulkhead, this auto-reset switch monitors supply-air temperature and shuts off the burners if the furnace overheats — typically caused by restricted airflow, a dirty filter, or a failing blower. It automatically closes and allows normal operation again once temperatures return to a safe range.
OEM vs. Generic: The 150°F trip temperature is specific to this furnace's design. The OEM switch guarantees the correct calibration, disc size, and terminal layout so the safety circuit performs exactly as engineered. Generic limits with approximate temperature ratings can cause short-cycling or fail to protect the heat exchanger, risking cracks and carbon-monoxide leaks.
Install difficulty: Easy (1/5). Turn off power at the furnace, unplug the two spade terminals, remove the mounting screws, and install the replacement in the same orientation. The job takes about 10–15 minutes. If the limit keeps tripping after replacement, check the air filter, ductwork, and blower speed to clear the underlying airflow restriction.