IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370155 is a genuine OEM auxiliary (rollout/secondary) limit switch designed for the GMT140-5D gas furnace and related Goodman and Amana models. This 120°F auto-reset control monitors temperature in the blower or vestibule area and interrupts the circuit if heat rises beyond safe limits — a critical backup to the primary high limit. Failed auxiliary limits often cause intermittent no-heat calls or short cycling.
Genuine Goodman OEM auxiliary limits are matched to the low 120°F setpoint and mounting footprint your furnace requires. Generic substitutes frequently ship with incorrect trip temperatures or bracket geometry, leading to premature nuisance trips and comfort complaints. Choosing OEM preserves manufacturer specs and warranty coverage.
Easy (1/5). Disconnect furnace power, note wire positions, slide off the spade connectors, unscrew the switch, and install the replacement. Typical time is 10–15 minutes. If the new switch trips again quickly, check blower operation and airflow before assuming a defective part.