The Goodman B1370155 is a genuine OEM auxiliary high-limit safety switch designed for the Goodman DHS80905CXA 80% AFUE gas furnace and compatible Goodman/Amana furnace platforms. This normally-closed thermal switch opens at approximately 120°F to shut down the burner or blower circuit if it detects abnormal heat, protecting the heat exchanger and surrounding cabinet from overheating. A failed or nuisance-tripping auxiliary limit is one of the most common causes of a furnace that starts, then shuts off on a safety lockout.
This is a genuine OEM Goodman switch calibrated to the exact factory trip point and mounting footprint, so it drops in without wiring adapters or bracket modification. Universal aftermarket limit switches may carry a different trip temperature or terminal orientation, which can cause premature lockouts or fitment issues. For a safety-critical component, matching the OEM spec is strongly recommended.
Rated Easy (1 of 3). Replacement typically takes 10–15 minutes: disconnect power, note the two spade terminals, unscrew the switch from the burner box or blower deck, and swap in the new unit. Basic hand tools only. Always verify power is off at the disconnect before servicing.