IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370155 is a genuine OEM auxiliary limit switch engineered for the AMS80704BNAA gas furnace and compatible Goodman/Amana 80% AFUE models. This normally-closed thermal safety control opens at approximately 120°F to protect the heat exchanger and blower compartment from overheating, shutting down the burners if airflow is restricted or a blower fault occurs. Replacing a failed limit switch restores safe, code-compliant furnace operation.
OEM vs. Generic: This is a true Goodman OEM component with the exact trip temperature, bracket geometry, and mounting hole pattern the AMS80704BNAA was designed around. Generic universal limits often require bending brackets or splicing leads and may trip at the wrong temperature, causing nuisance lockouts. Choosing OEM guarantees a bolt-in fit and correct safety response.
Install difficulty: Easy (1/5). Cut furnace power, disconnect the two spade terminals, remove two mounting screws, and reverse to install. Typically a 10-minute repair for a technician; a confident DIYer can complete it, but always de-energize the unit and verify airflow before restarting.
Backed by fast shipping and exact-fit assurance for National HVAC Parts customers.