The Goodman B1370155 is a genuine OEM 120°F auxiliary limit switch for AMS80703AXA 80% AFUE gas furnaces. This secondary high-limit is typically mounted on the blower deck or near the coil and cuts power if the cabinet overheats due to restricted airflow — a clogged filter, closed dampers, seized blower, or blocked return. It backs up the main limit and helps prevent heat-exchanger damage from chronic overheating.
OEM vs. Generic: The B1370155 uses Goodman's exact 120°F calibration and mounting geometry, so it protects at the engineered setpoint and seats flush against the deck for accurate sensing. Generic substitutes with different trip points or bracket shapes can cause nuisance shutdowns or delayed protection.
Installation difficulty: Easy. A 10–20 minute repair: disconnect power, photograph the wiring, unbolt the old switch, mount the replacement in the same orientation for good thermal contact, and reconnect the terminals. If the original tripped, correct the airflow restriction before restoring operation.