Overview

This is a genuine OEM X-13 ECM blower motor control (part number 1185284) for the ICP / Tempstar / Heil WAHM424A2 fan coil air handler. Rated at 1/2 HP, this constant-torque ECM (electronically commutated motor) drives the indoor blower wheel that moves conditioned air through the duct system. Unlike a standard PSC motor, the X-13 ECM runs at programmed torque settings selected by tap, delivering quieter operation, better airflow consistency, and higher efficiency. When this motor fails, you'll see weak or no airflow at the registers, intermittent blower operation, unusual noise, or a system that cools/heats but never reaches setpoint because air isn't moving. A failed module or worn bearings are the most common failure points.

Specifications

Spec Value
Part Number 1185284
Type X-13 ECM Blower Motor Control
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Motor Class Constant-Torque ECM (X-13)
Application Indoor Blower / Fan Coil
Fit OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP WAHM424A2 fan coil. It also fits the broader WAHM424 air handler series and other ICP/Tempstar/Heil/Comfortmaker fan coils that originally used the 1185284 1/2 HP X-13 ECM motor control. Confirm horsepower and the OEM part number on your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before servicing.
  2. Access — Remove the air handler blower compartment service panel.
  3. Document — Photograph all power and control/tap wiring and the blower wheel set-screw position before disconnecting.
  4. Remove — Loosen the blower wheel set screw, slide the assembly out, then unbolt the motor from the blower housing and transfer the wheel.
  5. Install — Mount the new ECM motor, reinstall the blower wheel at the documented depth, and reconnect power and tap wiring per your photo.
  6. Test — Restore power and verify smooth start-up, correct airflow, and quiet operation at each speed tap.

Signs You Need a Replacement

  • Weak airflow or no airflow at the supply registers
  • Blower won't start, or starts intermittently
  • Grinding, humming, or rattling noise from the blower compartment
  • System runs but never reaches thermostat setpoint due to poor air movement

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHM424A2 — 1/2 HP Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHM424A2 — 1/2 HP Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHM424A2 — 1/2 HP Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online