ICP X-13 ECM Fan Motor Control for WJA342000KTP0A1 — 1/2 HP | Ships Today
ICP

ICP X-13 ECM Fan Motor Control for WJA342000KTP0A1 — 1/2 HP | Ships Today

SKU: 1185846 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM ICP part 1185846 is an X-13 ECM motor control module rated at 1/2 HP, used as the constant-torque blower drive on ICP/Heil/Tempstar gas furnaces and air handlers including model WJA342000KTP0A1. Unlike a standard PSC motor, the X-13 is a programmed-tap ECM that holds steady torque across changing static pressure, delivering quieter operation and lower electricity draw. When this control fails you typically see a blower that won't start, runs at one fixed speed, hunts up and down, or trips on the control board. This is a direct factory replacement preset to the original equipment airflow taps.

Specifications

Spec Value
Part Number 1185846
Type X-13 ECM Motor Control
Brand ICP / Heil / Tempstar
Horsepower 1/2 HP
Motor Technology Constant-Torque ECM
Application Furnace Blower / Air Handler

Compatibility

Engineered for ICP, Heil, Tempstar, Comfortmaker and Carrier-family equipment using the 1/2 HP X-13 blower platform, including model WJA342000KTP0A1. Always confirm the part number stamped on your existing motor control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all motor and tap wiring before disconnecting.
  4. Remove — Unplug the line and control harnesses, release the motor mount band, and slide the blower assembly out; transfer the wheel and set screw position.
  5. Install — Mount the new X-13 control, reinstall the blower wheel, and reconnect each harness exactly per your photo.
  6. Test — Restore power and verify the blower ramps and holds steady torque in heat and cool.

Signs You Need a Replacement

  • Blower motor will not start or only hums
  • Airflow stuck on one speed or surging up and down
  • Intermittent no-heat / no-cool with the fan dead
  • Burning smell or visibly scorched control connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJA342000KTP0A1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJA342000KTP0A1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJA342000KTP0A1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.