Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP X-13 ECM Fan Motor Control for WJA336000KTP0A1 — 1/2 HP | Ships Today
ICP

ICP X-13 ECM Fan Motor Control for WJA336000KTP0A1 — 1/2 HP | Ships Today

SKU: 1185844 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM X-13 ECM fan motor control (part number 1185844) for the ICP/Heil/Tempstar model WJA336000KTP0A1. The X-13 is a 1/2 HP electronically commutated (ECM) constant-torque blower motor that drives the indoor air handler or furnace blower. Unlike older PSC motors, the X-13 uses a brushless DC design for quieter operation, lower power draw, and stable airflow against changing static pressure. Common failure symptoms include the blower failing to start, intermittent operation, unusual humming or buzzing, overheating, or the motor spinning up then shutting down on its internal protection. A failed ECM module will often leave the blower completely dead while the rest of the control board still powers up.

Specifications

Spec Value
OEM Part Number 1185844
Type X-13 ECM Motor Control
Brand ICP / Heil / Tempstar
Horsepower 1/2 HP
Motor Technology Constant-Torque ECM (brushless DC)
Application Indoor blower / air handler
Fitment OEM Replacement

Compatibility

Designed as a direct OEM replacement for ICP, Heil, and Tempstar model WJA336000KTP0A1. Because ICP shares platforms across its family brands, this X-13 module also appears in many comparable Comfortmaker and Day & Night air handlers using the same blower assembly. Always confirm the OEM part number 1185844 against your old unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the 5-pin control and power harnesses, then unbolt the ECM module from the motor end-bell.
  5. Install — Mount the new X-13 control, reseat the bolts, and reconnect each harness exactly per your photo.
  6. Test — Restore power, call for fan, and confirm smooth ramp-up and steady airflow.

Signs You Need a Replacement

  • Blower does not start even though the thermostat and control board are calling for fan.
  • Motor hums, buzzes, or briefly spins then stops.
  • Intermittent airflow or repeated overheating shutdowns.
  • Burnt-electronics smell or visible scorching on the control module.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJA336000KTP0A1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJA336000KTP0A1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJA336000KTP0A1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online