This is a genuine OEM X-13 ECM motor control / blower motor (part number 1185268) rated at 1/3 HP for the ICP WAXL184A1. The X-13 is a constant-torque electronically commutated motor that drives the indoor blower wheel, moving conditioned air through the duct system. Compared to a standard PSC motor it runs cooler, draws less power, and holds a programmed torque across changing static pressure. When an ECM blower motor fails you will see weak or no airflow, the motor humming without spinning, intermittent shutdowns, or error/diagnostic codes from the control board. A motor that runs hot, makes bearing noise, or only starts with a push is at the end of its service life.

Specifications

Spec Value
Part Number 1185268
Type X-13 ECM Constant-Torque Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/3 HP
Motor Technology ECM (Electronically Commutated)
Application Furnace / Air Handler Blower
Fits Model WAXL184A1

Compatibility

This X-13 ECM motor is the factory replacement for the ICP WAXL184A1 and is shared across matching Tempstar, Heil, and Comfortmaker air handlers and furnaces built on the same blower platform. Confirm the part number 1185268, the 1/3 HP rating, and the motor mount and shaft dimensions against your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the motor leads with a multimeter.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly if required.
  3. Document — Photograph the motor wiring harness, ground, and the blower wheel position on the shaft.
  4. Remove — Loosen the blower wheel set screw, unbolt the motor from the housing, and disconnect the power and control harness.
  5. Install — Mount the new X-13 motor, slide the blower wheel to the documented position and tighten the set screw, then reconnect the harness and ground per your photo.
  6. Test — Restore power and verify the blower ramps to the correct speed with steady, vibration-free airflow.

Signs You Need a Replacement

  • Weak airflow or no airflow at the registers
  • Motor hums or buzzes but will not spin up
  • Bearing noise, grinding, or wobble from the blower
  • Blower cycles on and off or throws a motor fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAXL184A1 — 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAXL184A1 — 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAXL184A1 — 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online