This is a genuine OEM X-13 ECM blower motor control (part #1185282) for the ICP WAHT304A1 air handler. The X-13 is a programmed constant-torque ECM (electronically commutated motor) rated 1/3 HP that drives the blower wheel to deliver conditioned air through the duct system. Unlike a standard PSC motor, the X-13 holds a steady torque across changing static pressure and runs more efficiently and quietly. Symptoms of a failing motor include no airflow on a heat or cool call, weak or surging airflow, the blower humming but not spinning, or the motor running hot and cycling on its internal overload. Because the control module is integrated, ECM motors typically fail electronically rather than mechanically.

Specifications

Spec Value
Part Number 1185282
Type X-13 ECM Motor Control (Constant Torque)
Brand ICP (Tempstar / Heil / Comfortmaker)
Horsepower 1/3 HP
Application Blower / Air Handler Fan
Fit OEM Direct Replacement

Compatibility

Designed as a direct-fit replacement for the ICP WAHT304A1 air handler blower assembly and shared across ICP-family units (Tempstar, Heil, Comfortmaker, Arcoaire) that use the 1185282 X-13 motor. Confirm horsepower (1/3 HP), motor frame, and shaft size match your existing blower motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the unit with a multimeter.
  2. Access — Remove the air handler blower compartment access panel and slide out the blower assembly.
  3. Document — Photograph the motor harness connections and the blower wheel set-screw position on the shaft.
  4. Remove — Loosen the blower wheel set screw, disconnect the motor plugs, unbolt the motor from the housing, and slide the wheel off the old shaft.
  5. Install — Mount the new X-13 motor, reinstall the blower wheel at the same shaft depth, retighten the set screw, and reconnect the harness per your photo.
  6. Test — Restore power and verify smooth, full airflow on a thermostat call with no vibration or noise.

Signs You Need a Replacement

  • No blower airflow when the system calls for heat or cool
  • Weak, surging, or inconsistent airflow
  • Motor hums but the blower wheel does not turn
  • Motor overheats and shuts down on its internal overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHT304A1 — 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHT304A1 — 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHT304A1 — 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online