Overview

This OEM X-13 ECM motor control module (part number 1185840) is the 1/3 HP electronically commutated blower drive for the ICP WJA330000K000A1 air handler. Unlike a standard PSC motor, the X-13 ECM holds a constant torque across multiple programmed taps, delivering quieter operation, steadier airflow, and meaningfully lower electricity use. The integrated control board reads the 24V tap signals from the furnace or air-handler control and drives the motor to the selected speed. When the module's electronics fail you'll see no blower operation, intermittent cutouts, error codes, or a motor that hums but won't spin. Replacing the X-13 control restores correct CFM and protects the rest of the system from short cycling.

Specifications

Spec Value
OEM Part Number 1185840
Type X-13 ECM Motor Control / Module
Brand ICP / Heil / Tempstar
Horsepower 1/3 HP
Motor Technology Constant-torque ECM (variable speed)
Control Signal 24V tap selection
Fits Model WJA330000K000A1

Compatibility

Direct OEM replacement for the ICP WJA330000K000A1 and matching Heil, Tempstar, and Comfortmaker air handlers using the 1/3 HP X-13 platform. Verify the HP rating and that your original motor is an X-13 (constant-torque) module before installing.

Installation Guide

  1. Safety First — Disconnect power at the air handler and verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly if required.
  3. Document — Photograph the 5-pin power harness, the 24V tap plug, and the tap positions in use.
  4. Remove — Unplug the harnesses, loosen the set screw, and separate the control module/motor from the blower housing.
  5. Install — Mount the new X-13 motor control, reconnect the power and tap harnesses, and set the same speed taps shown in your photo.
  6. Test — Restore power, call for blower, and confirm smooth ramp-up and correct airflow on each speed.

Signs You Need a Replacement

  • Blower won't run or only hums without spinning
  • Motor starts then drops out intermittently
  • Weak, fluctuating, or no airflow at the registers
  • Burning smell or visible scorching on the control module

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJA330000K000A1 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJA330000K000A1 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJA330000K000A1 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.