Overview

This is a genuine OEM X-13 ECM blower motor control (part number 1185839) rated at 1/3 HP for the ICP / Tempstar / Heil WJH424000KTP0A1 system. The X-13 is a constant-torque electronically commutated motor (ECM) that drives the indoor blower wheel, moving conditioned air through the duct system. Unlike a standard PSC motor, the X-13 maintains a programmed torque across changing static pressure, delivering quieter operation and higher efficiency. Common failure symptoms include the blower not starting, intermittent operation, buzzing or humming without rotation, overheating and thermal shutdown, or error/fault codes on the furnace control board. A failed ECM motor will leave the system unable to deliver heating or cooling even when the compressor and burners are working.

Specifications

Spec Value
Part Number 1185839
Type X-13 ECM Constant-Torque Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/3 HP
Voltage 120/240V
Application Indoor Furnace / Air Handler Blower
Fit OEM Direct Replacement

Compatibility

Engineered as a direct-fit OEM replacement for the ICP / Tempstar / Heil model WJH424000KTP0A1 and related Comfortmaker-family air handlers and gas furnaces using the 1185839 X-13 ECM motor module. Always confirm the part number on your existing motor label before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the unit with a multimeter before touching any wiring.
  2. Access — Remove the blower compartment service panel to expose the motor and blower assembly.
  3. Document — Photograph all motor and control connections, including the 5-pin and high-voltage plugs, before disconnecting anything.
  4. Remove — Unplug the motor harness, loosen the blower wheel set screw, remove the motor mount bolts, and slide the old motor out of the housing.
  5. Install — Transfer the blower wheel to the new motor shaft, mount the motor, reconnect the harness exactly per your photos, and torque the set screw on the shaft flat.
  6. Test — Restore power, call for blower operation, and confirm smooth ramp-up, correct airflow, and no fault codes.

Signs You Need a Replacement

  • Blower fails to start or starts only intermittently.
  • Humming or buzzing from the motor with no rotation.
  • Motor runs hot and trips on thermal overload.
  • Furnace control board reports a blower/motor fault code.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH424000KTP0A1 — OEM 1185839 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJH424000KTP0A1 — OEM 1185839 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH424000KTP0A1 — OEM 1185839 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.