Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP X-13 Blower Motor for WPG4304040LKA1 — 1/2 HP ECM | Ships Today
ICP

ICP X-13 Blower Motor for WPG4304040LKA1 — 1/2 HP ECM | Ships Today

SKU: 1186863 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM X-13 blower motor (part #1186863) is the 1/2 HP ECM (electronically commutated) indoor blower motor that circulates conditioned air through your ICP WPG4304040LKA1 packaged unit. X-13 motors are constant-torque ECMs that run far more efficiently and quietly than older PSC motors while holding steady airflow against duct static. The motor drives the blower wheel on every heating, cooling, and continuous-fan call. When it fails, you lose airflow entirely — no air from the registers — or you get weak airflow, overheating limit trips on a heat call, and frozen coils on a cooling call. Hard starting, hot-smelling windings, or a motor that hums but won't turn all indicate the motor or its module is failing.

Specifications

Spec Value
OEM Part Number 1186863
Type X-13 Constant-Torque ECM Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Application Indoor / furnace blower

Compatibility

Engineered for the ICP WPG4304040LKA1 packaged gas/electric unit and shared across ICP-family equipment (Tempstar, Heil, Comfortmaker, Arcoaire) specifying a 1/2 HP X-13 blower motor. Confirm horsepower, shaft, mounting, and motor-program plug match your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect switch, then verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel and slide out the blower assembly if needed.
  3. Document — Photograph the motor wiring, program/tap connections, and blower-wheel position on the shaft.
  4. Remove — Loosen the wheel set screw, pull the wheel, then unbolt the old motor from the blower housing.
  5. Install — Mount the new motor, reinstall the blower wheel at the same depth, tighten the set screw on the shaft flat, and reconnect power and program leads per your photo.
  6. Test — Restore power and confirm the blower ramps up smoothly and delivers full airflow on heat, cool, and fan calls.

Signs You Need a Replacement

  • No airflow or noticeably weak airflow from registers
  • Motor hums but the blower wheel won't spin
  • Furnace trips on high-limit or coil freezes from low airflow
  • Burning smell, hot windings, or loud bearing noise from the motor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4304040LKA1 — 1/2 HP ECM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4304040LKA1 — 1/2 HP ECM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4304040LKA1 — 1/2 HP ECM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online