This genuine OEM tubing pressure switch (part number 1178417) is the safety device that proves proper draft and venting on the ICP/Tempstar/Heil WPG3604115RKC1. Connected by tubing to the inducer or vent, it senses negative pressure and closes its contacts to confirm the combustion air path is clear before the control allows ignition. A failed or stuck switch — or a blocked, cracked, or disconnected hose — prevents the furnace from firing as a safety lockout, even when every other component is healthy. Symptoms include the inducer running but the unit never lighting, or short-cycling on a pressure fault.
| Spec | Value |
|---|---|
| Part Number | 1178417 |
| Type | Tubing / Air-Proving Pressure Switch |
| Brand | ICP / Tempstar / Heil |
| Function | Draft / Vent Safety Proving |
| Fit | OEM Replacement |
| Application | Gas Furnace |
Direct-fit OEM replacement for the ICP WPG3604115RKC1 packaged gas/electric unit and related Tempstar, Heil, and Comfortmaker furnaces using the same pressure-switch assembly. Verify the part number and pressure setpoint on your existing switch before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.