Overview

This genuine OEM tubing pressure switch (part #1178417) is the safety device that proves proper draft on the ICP/Heil/Tempstar WPG3304040LKC1 packaged unit. Before the control board allows the igniter and gas valve to energize, the inducer motor must pull a vacuum that closes this pressure switch through its sensing tube. This confirms the venting is clear and combustion gases can safely exhaust. A failed switch, a cracked tube, or a clogged port will stop the ignition sequence cold — the inducer runs but the burners never light. Replacing the switch with the correct factory part restores safe, reliable furnace operation.

Specifications

Spec Value
Part Number 1178417
Type Tubing Pressure / Draft Switch
Brand ICP / Heil / Tempstar
Control Voltage 24V
Function Combustion Draft Proving
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP unit WPG3304040LKC1 and the shared Heil, Tempstar, Comfortmaker, and Keeprite chassis. Confirm part number 1178417 and the original switch trip setpoint before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the control/burner access panel.
  3. Document — Photograph the two spade terminals and the sensing tube routing before disconnecting.
  4. Remove — Pull the wire terminals, slip off the rubber tube, and remove the mounting screws.
  5. Install — Mount the new switch, reattach the tube without kinks, and reconnect the terminals per your photo.
  6. Test — Restore power and run a heat cycle; confirm the inducer pulls the switch closed and the burners light.

Signs You Need a Replacement

  • Inducer motor runs but burners never ignite
  • Furnace locks out with a pressure-switch fault code
  • Switch fails a continuity test once the inducer is at full draft
  • Cracked, brittle, or disconnected sensing tube

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my ICP WPG3304040LKC1 — OEM 1178417 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the ICP WPG3304040LKC1 — OEM 1178417 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my ICP WPG3304040LKC1 — OEM 1178417 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.