Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WPH4484000RKA1 — 40VA 24V | Ships Today
ICP

ICP Transformer for WPH4484000RKA1 — 40VA 24V | Ships Today

SKU: WPH4484000RKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 24V control transformer assembly (parts 1176148 and 1172619) is the factory replacement for the ICP / Tempstar / Heil WPH4484000RKA1 heat pump. The transformer steps line voltage down to the 24-volt class 2 power that energizes the contactor coil, reversing valve solenoid, and low-voltage control circuit. Rated at 40VA, it supplies the steady control power the outdoor board and the reversing valve coil need to switch the system between heating and cooling. A shorted or open transformer kills all low-voltage operation — the thermostat goes dark, the contactor won't pull in, and the unit appears completely dead. Replacing it restores 24V control power and normal heat-pump operation.

Specifications

Spec Value
Part Numbers 1176148, 1172619
Type Control Transformer (24V Class 2)
Brand ICP / Tempstar / Heil
Rating 40 VA
Secondary Voltage 24V
Includes Reversing valve coil (24V)
Fitment OEM

Compatibility

Engineered as the direct replacement for the ICP WPH4484000RKA1 heat pump condensing unit. Because ICP builds for several brands, these components also service equivalent Tempstar, Heil, Comfortmaker, and Arcoaire outdoor units originally equipped with parts 1176148 and 1172619. Confirm the secondary voltage and VA rating against your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the transformer with a multimeter.
  2. Access — Remove the service panel to reach the electrical control box.
  3. Document — Photograph the primary and secondary lead connections and the reversing valve coil wiring before disconnecting.
  4. Remove — Label and disconnect the leads, then unbolt the transformer from the control panel.
  5. Install — Mount the new transformer, reconnect the primary to line voltage and the secondary to the 24V circuit per your photo.
  6. Test — Restore power and confirm 24V across the secondary, then verify the contactor and reversing valve respond to a thermostat call.

Signs You Need a Replacement

  • Thermostat is blank and the system is completely unresponsive.
  • No 24V measured across the transformer secondary.
  • Contactor and reversing valve won't energize on a call for heat or cool.
  • Transformer is hot, buzzing, or has a burnt smell.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPH4484000RKA1 — 40VA 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPH4484000RKA1 — 40VA 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPH4484000RKA1 — 40VA 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online