Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WPG3484130RKC1 — 40VA 208/230V to 24V | Ships Today
ICP

ICP Transformer for WPG3484130RKC1 — 40VA 208/230V to 24V | Ships Today

SKU: 1178431 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer provides the 24V low-voltage power that operates the control board, contactor coil, ignition control, and thermostat circuit on your ICP WPG3484130RKC1. Rated at 40VA with a dual 208/230V primary and a 24V secondary, it powers the entire control side of the unit. When it fails, the low-voltage circuit goes dead — no thermostat display, no call for heating or cooling, and no contactor engagement even though line voltage is present. This package includes the OEM transformer (part 1173691) and the 24V terminal barrier (part 1178431) for landing and isolating the low-voltage connections.

Specifications

Spec Value
Part Number 1173691 (transformer), 1178431 (barrier)
Type Control / Class 2 transformer
Brand ICP (Heil / Tempstar / Comfortmaker)
Rating 40 VA
Primary Voltage 208 / 230 VAC
Secondary Voltage 24 VAC

Compatibility

Engineered for the ICP WPG3484130RKC1 packaged unit and shared across many Heil, Tempstar, and Comfortmaker furnaces, air handlers, and package units using the same 40VA 208/230-to-24V control transformer. Confirm the printed part number on your existing transformer before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter on both line and low-voltage terminals.
  2. Access — Remove the control-panel service panel to expose the transformer and wiring barrier.
  3. Document — Photograph all primary and secondary wires before disconnecting.
  4. Remove — Disconnect the primary leads matched to your supply voltage, the 24V secondary leads, and unbolt the transformer from the panel; transfer the barrier if reusing landing terminals.
  5. Install — Mount the new transformer, land the correct primary taps for 208V or 230V, and reconnect the 24V secondary per your photo.
  6. Test — Restore power and confirm 24VAC across the secondary and a normal thermostat call.

Signs You Need a Replacement

  • No 24V control power — thermostat blank and unit unresponsive.
  • Repeatedly blown low-voltage fuse or tripped control circuit.
  • Buzzing, overheated, or visibly scorched transformer body.
  • Measured secondary voltage well below 24VAC under load.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3484130RKC1 — 40VA 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3484130RKC1 — 40VA 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3484130RKC1 — 40VA 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online