Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WPG3482115LKB1 — 40VA 208/230V to 24V | Ships Today
ICP

ICP Transformer for WPG3482115LKB1 — 40VA 208/230V to 24V | Ships Today

SKU: 1176032 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer (part #1173691) steps down 208/230-volt line power to the 24-volt control voltage that runs the thermostat, contactor coil, control board, and safety circuits in your ICP WPG3482115LKB1 system. Rated at 40VA, it supplies enough current for the full low-voltage control load. This listing includes the matching 24V terminal barrier/cover (part #1176032) for safe, code-compliant wiring. When a transformer fails — usually from a shorted thermostat wire, a seized contactor coil, or simple age — the entire 24V control circuit goes dead, and the system will not respond to the thermostat at all.

Specifications

Spec Value
Part Number 1173691 (transformer), 1176032 (24V barrier)
Type Control / Step-Down Transformer
Brand ICP / Heil / Tempstar
Rating 40 VA
Primary Voltage 208/230 VAC
Secondary Voltage 24 VAC
Fit OEM Replacement

Compatibility

This 40VA 208/230-to-24V transformer is the factory-specified control transformer for the ICP WPG3482115LKB1 and fits many Heil, Tempstar, and Comfortmaker units that use a dual-primary 40VA transformer. Confirm your primary voltage tap (208 vs. 230) before wiring.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter at the transformer primary.
  2. Access — Remove the electrical/control access panel.
  3. Document — Photograph the primary and secondary wiring and the voltage tap selection.
  4. Remove — Disconnect the primary and 24V secondary leads and unbolt the old transformer from its bracket.
  5. Install — Mount the new transformer, wire the correct primary tap for your line voltage, reconnect the 24V secondary, and install the terminal barrier.
  6. Test — Restore power and confirm 24VAC across the secondary and normal thermostat operation.

Signs You Need a Replacement

  • System completely unresponsive to the thermostat (no 24V control power).
  • No 24VAC measured across the secondary terminals.
  • Burnt smell or visibly charred/melted transformer housing.
  • Repeatedly blown low-voltage fuse or dead control board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3482115LKB1 — 40VA 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3482115LKB1 — 40VA 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3482115LKB1 — 40VA 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online