OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM control transformer steps down line voltage to the 24V control circuit that powers the thermostat, contactor coil, gas valve, and control board on your ICP / Tempstar / Heil WPG3302040RKB1 system. It accepts a 208/230V primary input and delivers a regulated 24V, 40VA secondary output. When a transformer fails, the entire low-voltage control system goes dead: the thermostat screen goes blank, the contactor will not pull in, and the unit will not start at all. A buzzing transformer, a blown low-voltage fuse, or a burnt smell at the control box are classic failure signs. This listing includes the matching 24V barrier (OEM 1176032) and transformer (OEM 1173691).
| Spec | Value |
|---|---|
| Part Number | 1173691 (TRANS 208/230>24 40VA), 1176032 (BARRIER 24V) |
| Type | Control / Class 2 Transformer |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| VA Rating | 40VA |
Engineered as a direct OEM replacement for the ICP / Tempstar / Heil WPG3302040RKB1 package unit. The 208/230V-to-24V 40VA configuration is shared across many ICP-family condensers, package units, and furnaces, but always confirm the printed voltage and VA rating on your original transformer before installing.