OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM control transformer steps line voltage down to the 24V control circuit on your ICP / Tempstar / Heil WPG3302040LKB1 system. It takes a 208/230V primary input and delivers a regulated 24V, 40VA secondary output that powers the thermostat, contactor coil, gas valve, and control board. A failed transformer kills the entire low-voltage system: the thermostat goes blank, the contactor will not energize, and the unit will not run. Buzzing, a repeatedly blown control fuse, or a scorched smell at the control box point to a bad transformer. This listing includes the matching 24V barrier (OEM 1176032) and transformer (OEM 1173691).
| Spec | Value |
|---|---|
| Part Number | 1173691 (TRANS 208/230>24 40VA), 1176032 (BARRIER 24V) |
| Type | Control / Class 2 Transformer |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| VA Rating | 40VA |
Engineered as a direct OEM replacement for the ICP / Tempstar / Heil WPG3302040LKB1 package unit. The 208/230V-to-24V 40VA configuration is shared across many ICP-family condensers, package units, and furnaces, but always confirm the printed voltage and VA rating on your original transformer before installing.