Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WPG3242060LKB1 — 40VA 208/230V to 24V | Ships Today
ICP

ICP Transformer for WPG3242060LKB1 — 40VA 208/230V to 24V | Ships Today

SKU: 1176032 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer (part 1173691) steps the incoming 208/230V line voltage down to the 24V low-voltage power that runs the thermostat, gas valve, ignition control, and relays in your ICP WPG3242060LKB1 unit. Rated at 40VA, it supplies enough current for the full 24V control circuit. The kit also includes the OEM 24V barrier (part 1176032) that isolates and protects the low-voltage terminals. When a control transformer fails, the entire low-voltage side goes dead — no thermostat display, no call for heat or cool, and no relay or contactor pull-in — even though line voltage is present at the unit.

Specifications

Spec Value
Part Number 1173691 (transformer), 1176032 (24V barrier)
Type Control / Class 2 Transformer
Brand ICP (Heil / Tempstar / Comfortmaker)
Primary Voltage 208/230V
Secondary Voltage 24V
Rating 40VA
Fit OEM Replacement

Compatibility

Engineered as the direct OEM replacement for the control transformer in the ICP WPG3242060LKB1 package unit, sold under the Heil, Tempstar, and Comfortmaker labels. Always confirm primary and secondary voltage and VA rating against the unit's wiring diagram before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage at the transformer primary with a multimeter.
  2. Access — Remove the control-panel service panel to reach the transformer.
  3. Document — Photograph all primary and secondary wires before disconnecting.
  4. Remove — Label and disconnect the leads, then unbolt the failed transformer and any old barrier from the mounting bracket.
  5. Install — Mount the new transformer and 24V barrier, then reconnect the primary and secondary leads exactly per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals and a normal call for heat/cool.

Signs You Need a Replacement

  • No power to the thermostat or control board with line voltage present
  • Contactors and relays will not pull in
  • Measured secondary voltage is 0V or well below 24V
  • Visible burn marks, melted housing, or a tripping low-voltage fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3242060LKB1 — 40VA 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3242060LKB1 — 40VA 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3242060LKB1 — 40VA 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online