This genuine ICP control transformer (OEM #1173691) steps line voltage down to the 24V control power that runs your contactor coil, thermostat circuit, and safety controls. Rated at 40VA with a 208/230V primary and a 24V secondary, it is the heart of the low-voltage system. This listing also covers the matching terminal barrier/cover (OEM #1176148) that protects the wiring connections. When a transformer fails — usually from an overloaded secondary, a shorted control wire, or age — the entire 24V system goes dead: the contactor won't pull in, the thermostat goes blank, and the unit will not respond to a cooling call. A repeatedly blown transformer almost always points to a short in the control wiring that must be corrected before replacement.
| Spec | Value |
|---|---|
| Part Number | 1173691 (transformer), 1176148 (barrier 24V 42-60) |
| Type | Control / Step-Down Transformer |
| Brand | ICP (Tempstar / Heil) |
| Capacity | 40 VA |
| Primary Voltage | 208 / 230 VAC |
| Secondary Voltage | 24 VAC |
Directly fits ICP/Tempstar/Heil condensing unit model WPA4484000RKA1 and related Comfortmaker, Heil, and Tempstar units using a 40VA 208/230-to-24V control transformer. Confirm primary voltage, VA rating, and secondary voltage before installing.