Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WJA330000KTP0B1 — 208/230V to 24V 40VA | Ships Today
ICP

ICP Transformer for WJA330000KTP0B1 — 208/230V to 24V 40VA | Ships Today

SKU: 1176032 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer steps 208/230V line voltage down to 24V to power the low-voltage control circuit on your ICP / Tempstar / Heil furnace or air handler. Rated at 40VA, it supplies the thermostat, contactor coil, gas valve, and control board. The kit pairs OEM transformer 1173691 with 24V barrier 1176032 for safe terminal isolation. A failed transformer is one of the most common no-heat / no-cool causes — when it burns open, the entire 24V control system goes dead. Symptoms include a blank thermostat, a system that will not respond to a call for heat or cool, or a visibly scorched/smelling transformer.

Specifications

Spec Value
Part Numbers 1173691 (Transformer), 1176032 (24V Barrier)
Type Step-Down Control Transformer
Brand ICP (Tempstar / Heil)
Primary Voltage 208/230V
Secondary Voltage 24V
Rating 40VA

Compatibility

Engineered as a direct-fit replacement for ICP model WJA330000KTP0B1 and shared ICP, Tempstar, Heil, and Comfortmaker platforms that use a 208/230V-to-24V 40VA control transformer. Always confirm the part number on your existing transformer before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control area.
  3. Document — Photograph all primary and secondary wires before disconnecting.
  4. Remove — Disconnect the line-voltage primary and 24V secondary leads, then unbolt the old transformer from its bracket.
  5. Install — Mount the new transformer, install the 24V barrier, and reconnect each lead per your photo.
  6. Test — Restore power and confirm 24V output across the secondary terminals.

Signs You Need a Replacement

  • Blank or unresponsive thermostat
  • No 24V at the control board or contactor coil
  • Burnt smell or scorched transformer housing
  • System will not start on a call for heat or cool

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WJA330000KTP0B1 — 208/230V to 24V 40VA | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WJA330000KTP0B1 — 208/230V to 24V 40VA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WJA330000KTP0B1 — 208/230V to 24V 40VA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online