OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM ICP control transformer (part #1177217) steps down 120V line voltage to the 24V control voltage required by your furnace or air handler's low-voltage circuit. Rated at 40VA, it powers the thermostat, gas valve, control board, contactors, and relays in the WFSR040A030A2 system. When a transformer fails, the entire control circuit goes dead: the thermostat screen goes blank, the blower and burners won't start, and no 24V is present at the control board. A buzzing transformer, a tripped internal fuse, or a burnt smell are all signs the original has shorted and needs replacement. This is a genuine OEM replacement built to the exact electrical specs of the original.
| Spec | Value |
|---|---|
| Part Number | 1177217 |
| Type | Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Rating | 40 VA |
| Primary Voltage | 120V |
| Secondary Voltage | 24V |
| Fit | OEM Direct Replacement |
Directly fits ICP model WFSR040A030A2 and is shared across many Tempstar, Heil, and Comfortmaker furnaces and air handlers that use a 120V-to-24V 40VA control transformer. Always confirm your old transformer's VA rating and voltage markings match before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.