Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for WFMR045A024A1 — 40VA 120/24V Control Transformer | Ships Today
ICP

ICP Transformer for WFMR045A024A1 — 40VA 120/24V Control Transformer | Ships Today

SKU: 1176944 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer (part #1176944) steps down 120V line voltage to the 24V control signal that runs your ICP, Tempstar, and Heil furnace or air handler. Rated at 40VA, it powers the thermostat circuit, gas valve, ignition control, and relays. When a transformer fails, the entire low-voltage control system goes dead — the thermostat screen blanks, the blower won't start, and no heating or cooling call is answered. A buzzing transformer, a tripped or blown low-voltage fuse, or a melted/burnt smell at the control box are classic signs of an overloaded or shorted unit. This is a direct factory replacement built to the original specification.

Specifications

Spec Value
Part Number 1176944
Type Control Transformer
Brand ICP (Tempstar / Heil)
Rating 40 VA
Primary Voltage 120V
Secondary Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Designed for ICP family equipment including model WFMR045A024A1 and other Tempstar, Heil, and Comfortmaker furnaces and air handlers that use a 40VA 120/24V control transformer. Always confirm the primary voltage and VA rating against the failed unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the furnace or air handler service panel.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Disconnect the primary (line) and secondary (24V) leads, then unbolt the old transformer from the control panel.
  5. Install — Mount the new transformer, reconnect primary and secondary leads exactly per your photo, and confirm the correct voltage tap.
  6. Test — Restore power and verify 24V across the secondary terminals and a normal control response.

Signs You Need a Replacement

  • No 24V output / dead thermostat and controls
  • Repeatedly blown low-voltage fuse
  • Audible buzzing or humming from the transformer
  • Burnt smell or visible scorching at the control box

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFMR045A024A1 — 40VA 120/24V Control Transformer | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFMR045A024A1 — 40VA 120/24V Control Transformer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFMR045A024A1 — 40VA 120/24V Control Transformer | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online