OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This 40VA control transformer (OEM part number 1177217) is the factory replacement for the ICP/Tempstar/Heil WFAR120D066B2 furnace. The transformer steps line voltage (120V) down to the 24V control voltage that powers the thermostat, control board, gas valve, igniter circuit, and relays. When it fails, the entire low-voltage control system goes dead — the thermostat blanks, the board loses 24V, and the furnace will not respond to a heat call. Transformers typically burn out from a 24V short, a seized load drawing excess current, or a voltage surge. This OEM-spec unit is rated at 40VA with a 120V primary and 24V secondary to match the original equipment exactly.
| Spec | Value |
|---|---|
| Part Number | 1177217 |
| Type | Control Transformer |
| Brand | ICP (Tempstar / Heil) |
| Rating | 40 VA |
| Primary Voltage | 120V |
| Secondary Voltage | 24V |
| Fits Model | WFAR120D066B2 |
Engineered as the OEM replacement for the ICP/Tempstar/Heil WFAR120D066B2 furnace. Verify the primary voltage (120V), secondary voltage (24V), and 40VA rating against your existing transformer before installing. This is the factory-matched control transformer for that model.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.