OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 40VA control transformer steps line voltage down to the 24V low-voltage power required by the control board, contactor coil, and reversing-valve circuit on ICP Tempstar Heil model WCH3602GKR500 heat pump units. Note: the parts referenced on this model page (1172574 COIL REV VLV 24V and 1175622 VALVE REV W/COIL 24V) are reversing-valve components — verify the correct transformer part number against your unit before ordering. When the transformer fails, the entire 24V control circuit goes dead: the thermostat is unresponsive, the contactor won't pull in, and defrost and reversing-valve functions stop. Failure is usually caused by a shorted coil or fan motor overloading the secondary, a control-circuit short, or age-related winding breakdown.
| Spec | Value |
|---|---|
| Referenced Part Numbers | 1172574, 1175622 |
| Type | Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Rating | 40 VA |
| Secondary Voltage | 24V |
| Primary Voltage | 208/240V |
Designed for the 24V control system in ICP Tempstar Heil model WCH3602GKR500 and related ICP-family heat pumps. Confirm primary voltage and the 40VA rating match your application.
Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.