This OEM control transformer (part number 1172028) provides the 24V low-voltage power for the ICP WAXM484A2 air handler. It converts the unit's 208/230V line voltage down to the 24V needed to run the thermostat, control board, relays, and safety circuits. With a 40VA rating it supplies adequate current for the system's control load. A failed transformer takes the whole low-voltage system offline — the thermostat goes blank, the blower and compressor never energize, and there is no 24V between R and C. Common causes include a shorted thermostat wire, a shorted or stuck contactor coil drawing excess current, or simple age and heat fatigue that opens the internal winding or thermal fuse.

Specifications

Spec Value
Part Number 1172028
Type Class 2 Step-Down Control Transformer
Brand ICP
Primary Voltage 208/230V
Secondary Voltage 24V
Rating 40VA
Fitment OEM Replacement

Compatibility

Direct OEM fit for the ICP WAXM484A2 and compatible Tempstar and Heil air handlers that use the 1172028 transformer. Verify your incoming supply is 208/230V before wiring the primary.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter at the line terminals.
  2. Access — Remove the service panel to reach the control board and transformer.
  3. Document — Photograph every primary and secondary connection before removing wires.
  4. Remove — Disconnect the 208/230V primary leads and the 24V secondary leads, then unbolt the transformer.
  5. Install — Mount the new transformer, reconnect the primary to the correct voltage tap and the secondary to the 24V circuit per your photos.
  6. Test — Restore power, confirm 24V across R and C, and verify the thermostat and unit respond to a call for heating or cooling.

Signs You Need a Replacement

  • No measurable 24V at the secondary while line voltage is present.
  • Thermostat is dark and the system will not start.
  • Overheated, discolored, or smoking transformer body.
  • Control fuse blows repeatedly even after rewiring checks.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WAXM484A2 — 40VA 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WAXM484A2 — 40VA 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WAXM484A2 — 40VA 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online