This genuine OEM ICP control transformer (part number 1172028) steps 208/230V line voltage down to 24V to power the thermostat, relays, and fan-coil control board in the WAHT424A1 air handler. Rated at 40VA, it feeds the entire low-voltage circuit. A failed transformer is among the most common causes of a fully dead control system — blank thermostat, no fan, no heat or cool — despite line power being present. Transformers typically fail from a shorted control wire, a stuck contactor, or a voltage surge.

Specifications

Spec Value
Part Number 1172028
Type Step-Down Control Transformer
Brand ICP / Tempstar / Heil
Rating 40VA
Primary Voltage 208/230V
Secondary Voltage 24V

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil WAHT424A1 fan coil air handler. Verify the primary/secondary voltages and 40VA rating against your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and confirm zero voltage with a multimeter.
  2. Access — Remove the air handler control-compartment service panel.
  3. Document — Photograph all primary and secondary leads before disconnecting.
  4. Remove — Label and disconnect the line-voltage and 24V leads, then unbolt the old transformer from its bracket.
  5. Install — Mount the new transformer and reconnect the primary to the correct 208 or 230V tap and the secondary to the 24V circuit per your photos.
  6. Test — Restore power and verify 24V at the secondary and normal control operation.

Signs You Need a Replacement

  • Blank thermostat and completely dead low-voltage system.
  • No 24V reading at the control board or thermostat terminals.
  • Burnt smell or scorched transformer windings.
  • Repeatedly blown control-board fuses after reset.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WAHT424A1 — 40VA 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WAHT424A1 — 40VA 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WAHT424A1 — 40VA 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.