OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This control transformer provides the 24V low-voltage power that drives the contactor coil, control board, and reversing-valve circuit on your ICP RHS102L0AA0AAAA heat pump. It steps 208/240V line voltage down to 24V at 40VA. A failed transformer kills the entire control circuit — the contactor won't energize, the thermostat may go dark, and neither the compressor nor the fan will start despite having line power. Common causes are voltage surges, a shorted secondary, and overheating from an overloaded control circuit.
| Spec | Value |
|---|---|
| Type | Control Transformer |
| Brand | ICP (Tempstar / Heil) |
| Primary Voltage | 208/240V |
| Secondary Voltage | 24V |
| Rating | 40VA |
| Application | Heat pump low-voltage control |
Engineered for the ICP/Tempstar/Heil RHS102L0AA0AAAA heat pump and shared across the RHS102 series. Confirm your current transformer's VA rating and voltage taps before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.