Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for RHS102H0CB0AAA — 24V 40VA Control Circuit | Ships Today
ICP

ICP Transformer for RHS102H0CB0AAA — 24V 40VA Control Circuit | Ships Today

SKU: 1172619 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This control transformer delivers the 24V low-voltage power that operates the contactor coil, control board, and reversing-valve circuit on your ICP RHS102H0CB0AAA heat pump. It steps 208/240V line voltage down to 24V at 40VA. When it fails, the whole low-voltage control circuit goes dead — the contactor won't pull in, the thermostat may go blank, and the compressor and fan never start even with line power present. Failures stem from voltage spikes, a shorted secondary, or overheating from an overloaded control circuit.

Specifications

Spec Value
Type Control Transformer
Brand ICP (Tempstar / Heil)
Primary Voltage 208/240V
Secondary Voltage 24V
Rating 40VA
Application Heat pump low-voltage control

Compatibility

Engineered for the ICP/Tempstar/Heil RHS102H0CB0AAA heat pump and shared across the RHS102 series condensing units. Verify your existing transformer's VA and voltage taps before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-panel service cover.
  3. Document — Photograph all primary and secondary connections before disconnecting.
  4. Remove — Disconnect the primary and secondary leads and unbolt the old transformer from the bracket.
  5. Install — Mount the new transformer, match the primary leads to the correct voltage tap, and reconnect the secondary per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals.

Signs You Need a Replacement

  • No 24V at the control board or thermostat
  • Contactor won't energize and the system never starts
  • Scorched, swollen, or burnt-smelling transformer
  • Repeatedly blown low-voltage fuses

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHS102H0CB0AAA — 24V 40VA Control Circuit | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHS102H0CB0AAA — 24V 40VA Control Circuit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHS102H0CB0AAA — 24V 40VA Control Circuit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online