This OEM 24V control transformer powers the low-voltage circuit — contactor coil, reversing-valve solenoid, defrost board, and thermostat — on your ICP Tempstar Heil RHS102H0AB0AAAA heat pump. It converts incoming line voltage to a regulated 24-volt secondary rated at 40VA. When a transformer fails, the entire control circuit goes dead: the contactor won't energize, the reversing valve won't shift, and the thermostat may lose power entirely. Watch for a blown low-voltage fuse, buzzing at the transformer, a burnt smell, or no 24V between the R and C terminals.
| Spec | Value |
|---|---|
| Primary OEM Part | 1172619 |
| Type | Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Secondary Voltage | 24V |
| Rating | 40VA |
| Fit | OEM Replacement |
Engineered for the ICP-built RHS102H0AB0AAAA heat pump and equivalent Tempstar, Heil, and Comfortmaker RHS102-series units. Confirm voltage and VA rating against your existing transformer before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.