Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Transformer for RHS048L0BB0AAAA — 24V 40VA Control | Ships Today
ICP

ICP Transformer for RHS048L0BB0AAAA — 24V 40VA Control | Ships Today

SKU: 1172619 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 24V control transformer/coil component covers the low-voltage control supply for the ICP/Tempstar/Heil RHS048L0BB0AAAA heat pump and includes the matching 24V coils (parts 1172619 and 1175367). It delivers the 24V power that energizes the contactor coil, reversing-valve solenoid, and thermostat circuit. When this component fails, the low-voltage side goes dead — a blank thermostat, an unresponsive contactor, and a heat pump that ignores the call for heating or cooling. Typical failures include an open winding, an internal short from overload, or damage caused by a shorted control wire. Installing the correct 24V / 40VA OEM replacement restores reliable control power and proper reversing-valve switching.

Specifications

Spec Value
Part Numbers 1172619, 1175367
Type 24V Control Transformer / Coil
Brand ICP / Tempstar / Heil
Output Voltage 24V
Rating 40VA
Fitment OEM

Compatibility

Designed for the ICP/Tempstar/Heil RHS048L0BB0AAAA heat pump and used across comparable ICP-family heat pumps sharing the same 24V control circuit and reversing-valve coil. Confirm primary voltage and secondary VA rating against the existing part before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control/service panel to reach the low-voltage section.
  3. Document — Photograph all primary and secondary wiring before disconnecting.
  4. Remove — Label leads, disconnect them, and unfasten the old component.
  5. Install — Mount the new unit and reconnect each lead to the matching terminal per your photo.
  6. Test — Restore power, confirm 24V on the secondary, and verify normal heat/cool switching.

Signs You Need a Replacement

  • Blank thermostat or dead low-voltage circuit
  • Reversing valve won't shift between heat and cool
  • No measurable 24V on the secondary
  • Repeated control-circuit failures or burnt smell

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHS048L0BB0AAAA — 24V 40VA Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHS048L0BB0AAAA — 24V 40VA Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHS048L0BB0AAAA — 24V 40VA Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online