Overview

This genuine OEM control transformer (part #1173691) steps 208/230V line power down to 24V to run the low-voltage control circuit on your ICP, Heil, or Tempstar WPA4484000RKB1 unit. Rated at 40VA, it powers the contactor coil, control board, and thermostat circuit. This listing ships with the matching 24V terminal barrier (part #1176148, 42-60) for a clean, code-correct connection. When a transformer fails, the entire 24V control system goes dead — no contactor pull-in, no fan, no cooling — even though high-voltage power is present. A fresh OEM transformer restores reliable control power.

Specifications

Spec Value
Part Number 1173691 (transformer), 1176148 (24V barrier)
Type Step-Down Control Transformer
Brand ICP / Heil / Tempstar
Primary Voltage 208/230V
Secondary Voltage 24V
Rating 40VA

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPA4484000RKB1 unit and related ICP-family equipment using a 40VA, 208/230V-to-24V control transformer. Verify primary/secondary voltages and VA rating against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph the primary (line) and secondary (24V) wiring and barrier before disconnecting.
  4. Remove — Disconnect all leads and unbolt the old transformer and barrier from the panel.
  5. Install — Mount the new transformer and barrier, then reconnect primary and secondary leads per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals with a multimeter.

Signs You Need a Replacement

  • No 24V control power; contactor won't pull in
  • Unit has line voltage but is completely unresponsive
  • Burned smell or scorched transformer housing
  • No measurable voltage across the secondary terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPA4484000RKB1 — OEM 1173691 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPA4484000RKB1 — OEM 1173691 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPA4484000RKB1 — OEM 1173691 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online