OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is a genuine OEM 40VA step-down control transformer (part number 1012722) for the ICP/Tempstar/Heil X8MPN075B12A1 gas furnace. The transformer reduces the incoming 115V line voltage to the 24V low-voltage control circuit that powers the thermostat, gas valve, igniter circuit, and control board. Rated at 40VA, it supplies enough current for the full low-voltage load of a modern furnace. When a transformer fails, the entire control system goes dead: the thermostat screen may go blank, the furnace will not respond to a heat call, and the unit will appear completely unresponsive even though line power is present. A buzzing transformer, a blown low-voltage fuse on the control board, or a burnt smell near the control area are all classic signs of transformer failure.
| Spec | Value |
|---|---|
| Part Number | 1012722 |
| Type | Step-Down Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Primary Voltage | 115V |
| Secondary Voltage | 24V |
| Rating | 40VA |
| Fits Model | X8MPN075B12A1 |
Designed as the factory replacement transformer for the ICP/Tempstar/Heil X8MPN075B12A1 furnace. The 115V-to-24V, 40VA configuration is also common across many ICP-family furnaces — verify your existing transformer is rated 115V primary / 24V secondary / 40VA before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.