Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Ignitor Electrode for RGS300SSFA0AAAA — Direct Spark | Ships Today
ICP

ICP Spark Ignitor Electrode for RGS300SSFA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode (part number 1179966) for ICP, Tempstar, and Heil gas furnaces. The electrode delivers the high-voltage spark that ignites the burner gas at startup and, in many designs, also senses the resulting flame to confirm ignition. Its ceramic insulator and electrode tip degrade with heat cycling, and the gap can widen or carbon up, leading to delayed ignition, repeated ignition lockouts, or no ignition at all. A new electrode restores a strong, reliable spark and consistent burner light-off.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignitor Electrode
Brand ICP / Tempstar / Heil
Insulator Ceramic
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RGS300SSFA0AAAA gas furnace and other RGS300-series units that use the 1179966 ignitor electrode. Confirm your existing electrode part number and bracket orientation before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode mounting, wire routing, and gap position before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from the burner assembly.
  5. Install — Mount the new electrode, confirm proper spark gap and burner alignment, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle for prompt, reliable light-off.

Signs You Need a Replacement

  • No spark or weak/intermittent spark at the burner.
  • Delayed ignition or rough burner light-off.
  • Repeated ignition lockouts on a call for heat.
  • Cracked ceramic insulator or carbon-fouled electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SSFA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SSFA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SSFA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online