Overview

This genuine OEM ignitor electrode (part 1179966) provides spark ignition for the burner in the ICP Tempstar/Heil RGS210SFCA0AAAA gas/electric package unit. On a heat call, the control board sends high voltage to the electrode tip, generating the spark that lights the gas at the burner. The same or a paired electrode often serves as the flame-sensing rod, confirming the burner has lit. Because the electrode sits in the harsh, high-temperature burner area, the ceramic insulator can crack and the metal rod can erode or carbon-foul over time, causing no-ignition, delayed light-off, or short-cycling on flame loss. Replacing a worn electrode restores fast, reliable burner ignition.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignition Electrode
Brand ICP / Tempstar / Heil
Function Direct Spark Burner Ignition
Insulator Ceramic
Fit OEM Replacement

Compatibility

Designed for the ICP Tempstar/Heil RGS210SFCA0AAAA and related RGS210-series units using the 1179966 ignitor electrode. Match the part number and electrode geometry to your existing component before ordering, as gap and bracket shape are model-specific.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power at the disconnect and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and the ignition lead before disconnecting.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode from the burner bracket.
  5. Install — Mount the new electrode, maintaining the factory spark gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, then confirm clean spark and a steady burner light-off on a heat call.

Signs You Need a Replacement

  • No spark or weak spark at the burner
  • Cracked or chipped ceramic insulator
  • Repeated ignition lockouts or delayed light-off
  • Carbon buildup or erosion on the electrode rod

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SFCA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SFCA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SFCA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online