Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter (Ignitor/Sparker) for RGS180LSAA0AAAA — Ships Today
ICP

ICP Spark Igniter (Ignitor/Sparker) for RGS180LSAA0AAAA — Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM spark igniter (part number 1184216, "IGNITOR SPARKER") provides the high-voltage spark that lights the burners on the ICP/Tempstar/Heil RGS180LSAA0AAAA gas furnace. On a heat call, the control board sends voltage to the igniter, which arcs across its electrode gap to ignite the gas at the burner. Unlike a hot surface igniter that glows, this is a direct-spark style component, so a worn electrode, cracked ceramic insulator, or carbon buildup on the tip will cause no-light or delayed-ignition faults. Typical symptoms are a furnace that clicks but won't fire, repeated ignition lockouts, intermittent heat, or burners that light with a delayed "whoomph."

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter (Direct Spark)
Brand ICP (Heil / Tempstar)
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Engineered for the ICP RGS180LSAA0AAAA and related ICP/Heil/Tempstar/Comfortmaker gas furnaces that use this direct-spark ignition assembly. Verify the electrode shape and mounting bracket match your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position, gap, and wire routing before removal.
  4. Remove — Disconnect the ignition lead, remove the mounting screw(s), and lift out the old igniter without touching the ceramic with bare fingers.
  5. Install — Mount the new igniter, restoring the factory electrode gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, run a heat cycle, and confirm a strong spark and clean burner light-off.

Signs You Need a Replacement

  • Furnace clicks/sparks but burners won't ignite.
  • Repeated ignition lockout or error codes.
  • Cracked ceramic insulator or eroded electrode tip.
  • Delayed ignition with a rough or loud light-off.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180LSAA0AAAA — Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180LSAA0AAAA — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180LSAA0AAAA — Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.