Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180SSAA0AAAA — OEM Part 1184216 | Ships Today
ICP

ICP Spark Igniter for RGS180SSAA0AAAA — OEM Part 1184216 | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM spark igniter (part number 1184216) for the ICP/Heil/Tempstar RGS180SSAA0AAAA gas furnace. On spark-ignition systems, this electrode generates the high-voltage arc that lights the burner gas at the start of each heat cycle and, on many designs, also serves as the sense rod that proves flame. A worn, cracked, or carbon-fouled igniter produces a weak or missing spark, leading to ignition lockout, delayed ignition with a rumble, or short-cycling on a failed flame-proving signal. This direct-fit OEM electrode restores reliable light-off with the correct gap and mounting geometry.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Electrode
Brand ICP (Heil / Tempstar / Comfortmaker)
Ignition Method Direct Spark
Fit OEM direct replacement
Model RGS180SSAA0AAAA

Compatibility

Engineered for the ICP RGS180SSAA0AAAA furnace and shared across many Heil, Tempstar, and Comfortmaker spark-ignition gas furnaces using the same burner assembly. Verify your furnace uses a spark igniter (not a hot surface igniter) before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter position, gap, and ignition lead routing.
  4. Remove — Disconnect the high-voltage ignition lead and unscrew the igniter from the burner bracket.
  5. Install — Mount the new igniter, confirm the spark gap and electrode position over the burner, and reconnect the lead.
  6. Test — Restore gas and power and verify a strong spark and clean burner light-off.

Signs You Need a Replacement

  • Weak, intermittent, or absent spark at the burner
  • Cracked ceramic insulator or carbon buildup on the electrode
  • Furnace locks out after several failed ignition attempts
  • Delayed ignition with a noticeable rumble or flame roll

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SSAA0AAAA — OEM Part 1184216 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SSAA0AAAA — OEM Part 1184216 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SSAA0AAAA — OEM Part 1184216 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR