This is the genuine OEM spark igniter / sparker (ICP part number 1184216) for the ICP / Tempstar / Heil RGS180SREA0AAAA furnace. A spark igniter uses a high-voltage electrode positioned at the burner to create a repeating arc that lights the gas on each call for heat. On ignition, the control board sends high voltage to the electrode; the spark jumps the gap to the burner ground, igniting the gas-air mixture, and the system then proves flame before continuing. A worn or cracked igniter — eroded electrode tip, cracked ceramic insulator, or carbon-fouled gap — leads to delayed ignition, rough light-off, repeated lockouts, or no ignition at all. This direct-fit OEM sparker restores a strong, consistent arc and the correct electrode gap so the furnace lights cleanly every cycle. Always install with the factory-specified gap and a sound ground for reliable ignition.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Sparker Electrode
Brand ICP / Tempstar / Heil
Function High-voltage spark ignition of burner
Mounting Burner-mounted electrode assembly

Compatibility

Designed for the ICP / Tempstar / Heil RGS180SREA0AAAA gas furnace and related RGS-series units using a spark ignition system. Confirm the OEM number (1184216) and electrode style against your original before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position, gap, and wiring before removal.
  4. Remove — Unplug the high-voltage lead and unscrew the old igniter from the burner bracket.
  5. Install — Mount the new sparker, set the factory-specified electrode gap, and reconnect the ignition lead and ground.
  6. Test — Restore gas and power, then run a heat cycle and confirm a strong, immediate spark and clean burner light-off.

Signs You Need a Replacement

  • Delayed ignition or a rough, noisy light-off
  • Repeated ignition lockouts after several failed attempts
  • Weak, intermittent, or no visible spark at the burner
  • Cracked ceramic insulator or eroded electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SREA0AAAA — OEM 1184216 Sparker | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SREA0AAAA — OEM 1184216 Sparker | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SREA0AAAA — OEM 1184216 Sparker | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.