Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Spark Igniter for RGS180SFCA0AAAA – OEM 1184216 | Ships Today
ICP

ICP Spark Igniter for RGS180SFCA0AAAA – OEM 1184216 | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM spark igniter / sparker electrode (part number 1184216) for the ICP / Tempstar / Heil RGS180SFCA0AAAA gas furnace. The spark igniter generates the high-voltage arc that lights the burner gas on each heat call. A cracked ceramic insulator, eroded electrode tip, carbon buildup, or an incorrect spark gap leads to delayed ignition, repeated ignition lockouts, no heat, or a furnace that clicks but never lights. Replacing a worn igniter with the exact factory electrode restores fast, reliable burner ignition and proper spark gap geometry.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Sparker Electrode
Brand ICP / Tempstar / Heil
Ignition Style Spark / Direct Spark Ignition
Fit OEM exact-fit
Model RGS180SFCA0AAAA

Compatibility

Engineered for the ICP RGS180SFCA0AAAA and shared across spark-ignition ICP-family gas furnaces carrying the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Match the mounting bracket, electrode shape, and spark gap to your existing igniter before installing.

Installation Guide

  1. Safety First – Shut off the gas supply, disconnect electrical power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner-compartment service panel.
  3. Document – Photograph the igniter position, spark gap, and lead routing before disconnecting.
  4. Remove – Disconnect the high-voltage ignition lead and unscrew the old igniter from the burner assembly.
  5. Install – Mount the new 1184216 igniter, confirm the spark gap matches spec, and reconnect the ignition lead per your photos.
  6. Test – Restore gas and power, start a heat call, and verify the burner lights promptly with a strong, consistent spark.

Signs You Need a Replacement

  • Furnace clicks or sparks but the burner will not light
  • Repeated ignition lockouts or no-heat conditions
  • Cracked ceramic insulator or eroded electrode tip
  • Weak, intermittent, or misaligned spark

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SFCA0AAAA – OEM 1184216 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SFCA0AAAA – OEM 1184216 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SFCA0AAAA – OEM 1184216 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online